[導讀]: 美國家用商用電池標準UL2054 (Ed.3)第3版于2021年11月17日正式發(fā)布,此次標準較比上一版(第2版)更新的重要內容如下: 更新一:Added general construction requirements for wiri...
美國家用商用電池標準UL2054 (Ed.3)第3版于2021年11月17日正式發(fā)布,此次標準較比上一版(第2版)更新的重要內容如下:
更新一:
Added general construction requirements for wiring and terminals; 6.3
增加線(xiàn)材和端子的一般結構要求,涉及6.3章節。
當考慮到電池組內導線(xiàn)可能承受的溫度、電流和電壓時(shí),導線(xiàn)應該絕緣且可接受;接線(xiàn)頭和連接處應通過(guò)機械方式緊固,并應提供電氣接觸,且在連接和端子上沒(méi)有應力。導線(xiàn)應該安全,并遠離鋒利的邊緣或其他可能危及導線(xiàn)絕緣的部分。
標準原文:
6.3.1 Wiring shall be insulated and acceptable for the purpose, when considered with respect to temperature, current, and voltage to which the wiring is likely to be subjected within the battery pack.
6.3.2 The wiring splice or connection shall be mechanically secured and shall provide electrical contact without strain on connections and terminals. Wiring shall be secured and routed away from sharp edges or other parts that may compromise wiring insulation.
更新二:
Made miscellaneous revisions throughout the Standard; Sections 2 – 5, 6.1.2 – 6.1.4, 6.5.1, 8.1, 8.2, 11.10, 12.13, 13.3, 14.7, 15.2, 16.6, Section 23 title, 24.1, Appendix A.
對整個(gè)標準進(jìn)行了雜項內容的修訂,涉及章節:2–5, 6.1.2–6.1.4, 6.5.1, 8.1, 8.2, 11.10, 12.13, 13.3, 14.7, 15.2, 16.6, Section 23 title, 24.1, Appendix A此類(lèi)別主要是修訂標準中的描述,調整條款順序等,標準條款內容無(wú)實(shí)質(zhì)性變化。
更新三:
Clarified requirements for adhesive labels; Section 29, 30.1, 30.2
明確不干膠標簽的具體要求,涉及章節:29, 30.1, 30.2
30.1 The markings required for compliance to this standard shall be legible and permanent such asetched, adhesive labels, etc. An adhesive-backed label shall comply with the requirements in UL 969, forthe intended exposure conditions and surface adhered to.
29標簽性能測試:基本等同于IEC/UL 62368-1中的標簽擦拭測試。
30.1:對于預期的暴露條件和粘貼的表面,不干膠標簽需要符合UL969的要求。
Exception: Adhesive labels may be alternately evaluated to the Label Permanence Test in Section 29.
例外:不干膠標簽可以按照第29章規定的標簽耐久性測試進(jìn)行替代評估。
更新四:
Made Limited Power Source Test an optional requirement: 7.1
LPS測試作為可選要求,涉及章節:7.1
7.1 b) Section 15, Limited Power Source Test, is an optional requirement only carried out upon manufacturer’s request
7.1 b) 第15章節LPS測試,是一個(gè)可選要求,僅當制造商提出要求時(shí)才進(jìn)行測試。
更新五:
Clarified the external resistance in the test in 11.11.
明確11.11章節短路測試的阻抗要求。
11.11 One of the above five test sample battery packs, tested at 20 ±5 °C (68 ±9 °F) shall be evaluated with the following additional conditions in place. The terminals are to be subjected to a short circuit condition with a resistance that is capable of withstanding the short-circuit current and creating a short circuit condition with a total external resistance of 80 ±20 mΩ. The test is to be conducted on a tissue paper covered soft wood surface and the sample battery pack and bare conductor is to be covered with a single layer of cheesecloth.
變更前:5個(gè)樣品中的1個(gè)樣品,在20±5°C條件下,用一根至少16AWG的裸銅線(xiàn)短路電池的端子,未明確裸銅線(xiàn)的阻抗。
變更后:取消裸銅線(xiàn)的要求,明確短路回路阻抗為80±20mΩ。
免責聲明:部分文章信息來(lái)源于網(wǎng)絡(luò )以及網(wǎng)友投稿,本網(wǎng)站只負責對文章進(jìn)行整理、排版、編輯,是出于傳遞 更多信息之 目的,并不意味著(zhù)贊同其觀(guān)點(diǎn)或證實(shí)其內容的真實(shí)性,如本站文章和轉稿涉及版權等問(wèn)題,請作者在及時(shí)聯(lián)系本站,我們 會(huì )盡快處理。官方所有內容、圖片如未經(jīng)過(guò)授權,禁止任何形式的采集、鏡像,否則后果自負!
標題:標準更新丨美國家用商用電池標準UL2054 (Ed.3)更新解讀 地址:http://www.13hz.cn/newsDetail/59
您可能關(guān)注的內容
為國內外進(jìn)出口企業(yè)提供最為優(yōu)質(zhì)全面的檢測認證服務(wù)
官方微信:18566797115(倍科檢測)
工作時(shí)間:9:00-18:00
工作時(shí)間:9:00-18:00(節假日除外)
歡迎咨詢(xún)客服
倍科檢測:為全球進(jìn)出口企業(yè)提供專(zhuān)業(yè)高效的檢測認證服務(wù),包括:日本TELEC認證、日本JATE認證、埃及NTRA認證和韓國KCC認證。
Copyright?倍科電子技術(shù)服務(wù)(深圳)有限公司 版權所有 粵ICP16089192號